Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1976 1
1979 1
2009 1
2014 2
2015 2
2017 1
2018 1
2020 1
2021 2
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

12 results

Results by year

Filters applied: . Clear all
Page 1
Characterizing Hygroscopic Materials via Droplet Evaporation.
Shukla P, Jagdhari T, Fugaro AP, Boreyko JB. Shukla P, et al. Langmuir. 2020 Mar 3;36(8):1871-1877. doi: 10.1021/acs.langmuir.9b02840. Epub 2020 Feb 18. Langmuir. 2020. PMID: 32068407
Current techniques for quantifying the hygroscopicity of materials, such as the use of a tandem differential mobility analyzer or a gravimetric vapor sorption analyzer, require complex and expensive setups. ...By controlling the temperature of the droplet to corresp …
Current techniques for quantifying the hygroscopicity of materials, such as the use of a tandem differential mobility analyzer or a g …
Spurious Resonance of the QCM Sensor: Load Analysis Based on Impedance Spectroscopy.
Burda I. Burda I. Sensors (Basel). 2023 May 21;23(10):4939. doi: 10.3390/s23104939. Sensors (Basel). 2023. PMID: 37430852 Free PMC article.
In this range, there are many applications in the field of chemical sensors or biosensors, such as VOC sensors, humidity sensors, or dew point sensors. The evolution of D factor with increasing medium viscosity is significantly different for spurious resonances comp …
In this range, there are many applications in the field of chemical sensors or biosensors, such as VOC sensors, humidity sensors, or dew
Evaluation of sulfur trioxide detection with online isopropanol absorption method.
Xiong J, Li Y, Wang J, Yang Y, Zhu T. Xiong J, et al. J Environ Sci (China). 2018 Oct;72:25-32. doi: 10.1016/j.jes.2017.11.026. Epub 2017 Dec 8. J Environ Sci (China). 2018. PMID: 30244748
Measurement of the SO(3) concentration in flue gas is important to estimate the acid dew point and to control corrosion of downstream equipment. SO(3) measurement is a difficult question since SO(3) is a highly reactive gas, and its concentration is generally two or …
Measurement of the SO(3) concentration in flue gas is important to estimate the acid dew point and to control corrosion of dow …
Seasonal Dynamics of Photochemical Performance of PS II of Terrestrial Mosses from Different Elevations.
Hao J, Xu X, Zhang L. Hao J, et al. Plants (Basel). 2021 Nov 28;10(12):2613. doi: 10.3390/plants10122613. Plants (Basel). 2021. PMID: 34961084 Free PMC article.
We examined the seasonal dynamics of photochemical performance of PS II through the measuring of chlorophyll fluorescence of 12 terrestrial mosses in situ from five different elevations by Photosynthesis Yield Analyzer MINI-PAM-II, along with the seasonal changes of climat …
We examined the seasonal dynamics of photochemical performance of PS II through the measuring of chlorophyll fluorescence of 12 terrestrial …
[Specialized products for dietary correction of the diet of patients with non-alcoholic steatohepatitis].
Vorobyeva VM, Vorobyeva IS, Morozov SV, Sasunova AN, Kochetkova AA, Isakov VA. Vorobyeva VM, et al. Vopr Pitan. 2021;90(2):100-109. doi: 10.33029/0042-8833-2021-90-2-100-109. Epub 2021 Mar 11. Vopr Pitan. 2021. PMID: 34019353 Russian.
The mass fraction of moisture in the SP was determined by the thermo-gravimetric method on a humidity analyzer, and the water activity was determined by measuring the dew point. ...
The mass fraction of moisture in the SP was determined by the thermo-gravimetric method on a humidity analyzer, and the water activit …
New phase equilibrium analyzer for determination of the vapor-liquid equilibrium of carbon dioxide and permanent gas mixtures for carbon capture and storage.
Ke J, Parrott AJ, Sanchez-Vicente Y, Fields P, Wilson R, Drage TC, Poliakoff M, George MW. Ke J, et al. Rev Sci Instrum. 2014 Aug;85(8):085110. doi: 10.1063/1.4891796. Rev Sci Instrum. 2014. PMID: 25173315
A high-pressure, phase equilibrium analyzer incorporating a fiber-optic reflectometer is described. The analyzer has been designed for measuring the vapor-liquid equilibrium data of multi-component mixtures of carbon dioxide and permanent gases, providing a novel to …
A high-pressure, phase equilibrium analyzer incorporating a fiber-optic reflectometer is described. The analyzer has been desi …
Simultaneous Online Measurement of H2O and CO2 in the Humid CO2 Adsorption/Desorption Process.
Yu Q, Ye S, Zhu J, Lei L, Yang B. Yu Q, et al. Anal Sci. 2015;31(8):757-61. doi: 10.2116/analsci.31.757. Anal Sci. 2015. PMID: 26256597 Free article.
A dew point meter (DP) and an infrared (IR) CO2 analyzer were assembled in a humid CO2 adsorption/desorption system in series for simultaneous online measurements of H2O and CO2, respectively. ...
A dew point meter (DP) and an infrared (IR) CO2 analyzer were assembled in a humid CO2 adsorption/desorption system in …
On the calibration of continuous, high-precision delta18O and delta2H measurements using an off-axis integrated cavity output spectrometer.
Wang L, Caylor KK, Dragoni D. Wang L, et al. Rapid Commun Mass Spectrom. 2009 Feb;23(4):530-6. doi: 10.1002/rcm.3905. Rapid Commun Mass Spectrom. 2009. PMID: 19142848
In this report, we develop a relatively simple pumping system coupled to a dew point generator to calibrate an ICOS-based instrument (Los Gatos Research Water Vapor Isotope Analyzer (WVIA) DLT-100) under various pressures using liquid water with known isotopi …
In this report, we develop a relatively simple pumping system coupled to a dew point generator to calibrate an ICOS-based inst …
Genotypic variation in carboxylation of tomatoes.
Augustine JJ, Stevens MA. Augustine JJ, et al. Plant Physiol. 1976 Feb;57(2):325-33. doi: 10.1104/pp.57.2.325. Plant Physiol. 1976. PMID: 16659476 Free PMC article.
The gas exchange characteristics of 24 genotypes of Lycopersicon esculentum Mill. and one of L. minutum were measured with an infrared gas analyzer and dew point hygrometer in an open system. Net carbon exchange (NCE) and transpiration rate were measured at 5 …
The gas exchange characteristics of 24 genotypes of Lycopersicon esculentum Mill. and one of L. minutum were measured with an infrared gas …
[Theoretical and practical aspects of development of biscuits with a modified carbohydrate profile for patients with type 2 diabetes].
Kochetkova AA, Vorobyova VM, Vorobyova IS, Sharafetdinov KK, Sarkisyan VA, Semin MO, Savenkova TV, Soldatova EA, Osipov MV. Kochetkova AA, et al. Vopr Pitan. 2015;84(6):122-31. Vopr Pitan. 2015. PMID: 29378107 Russian.
Determination of physic-chemical and organoleptic characteristics of biscuits was carried out by standard methods. The water activity was determined on the analyzer using a cooled mirror dew point sensor, structural-mechanical properties - on texturename with …
Determination of physic-chemical and organoleptic characteristics of biscuits was carried out by standard methods. The water activity was de …
12 results